Principle :
The EUROLASE laser barriers have been designed for applications requesting a long distance detection and in stringent environments (dusts, flames, fog, rain, snow).
The system is composed of 2 separated modules (transmitter and receiver), that have to be installed one in front the other one. The transmitter generates an infrared pulsed beam (invisible). If a moveable object or product crosses, the beam is cut. This will be detected by the receiver.
The transmitter is available in standard or cooled version, and it will be associated to a receiver corresponding to the output required type, (commutation frequency, sensibility threshold, …).
|
| |
|
| |
Applications :
-
Detection of oversized vehicles at tunnel entry side
-
Long ranges safety barriers
-
Detection of hot products inside furnaces, with no interference of the flames
-
Detection of products breakage on line
-
Protection of ships masts
-
Cutting check on continuous casting machine
-
Continuous traveling products counting (bars, bottles of glass, tubes, …)
|
| |
|
| |
Many references :
3M, CECELEC, CLI, COGEMA, GTS, HBL,
HANSAPORT, KRUPP HOESCH, AM,
PORT TALBOT, POSCO, SAM, SAPRR,
SES, SOLLAC, THYSSEN, VALDUNE,
VALLOUREC Ville de Paris, Monaco, UGINE... |
| |
|
| |
|
| |
|
| |
Technical data of the HLS 03 transmitter : |
| |
Range
|
800 m max. |
| Transmitter |
laser diode AsGA, 850 nm, IR |
| Divergence |
8 mrad |
| Pulses frequency |
300 Hz max. (1000 Hz max. for HLS-03 T) |
| Pulses width |
20 ns |
| Power supply |
24 VDC +/- 20% (same for receiver) |
| Consumption |
50 mA max. |
| Operation indicator |
green LED, continuous |
| Protection |
IP 65 |
| Optical emission power |
1,3 W max. |
| IEC 825 / 1994 laser class |
class 1 |
| Connection cable |
L = 2 m, shielded silicone |
| Dimensions |
Standard version: L 258 x diam. 57 mm
cooled version: L 258 x diam. 76 mm |
| Cabinet |
stainless steel in standard (-20… +55ºC) or cooled version |
|
| |
|
| |
| Receiver |
HLS 03 |
HLS 03 T |
HLS 03 K |
| Receiver |
photodiode 850 nm ± 15nm / interferential filter |
| Detection frequency |
100 Hz ± 10%
|
650 Hz ± 10% |
100 Hz ± 10% |
| Output min. hold time |
300 à 400 ms |
300 à 400 ms |
300 à 400 ms |
| Response time |
10 à 15 ms |
2 ms |
10 à 15 ms |
| Adjustable |
800 ms max. |
350 ms max. |
350 ms max. |
| Output relay |
inverter contact 2 A / 30 VDC / 125 VAC |
| Threshold |
only
HLS 03K / 100 ohms min. / 0…24 VDC
|
|
| |
|
| |
Download : |
|
| |
|
|
|